33
07 - 2009
When this mode has been selected, if IN3 is connected to low, the coin exit sensor goes
inactive (OFF) to be able to carry out a test to see if it is operating. The confirmation of the
test is carried out on pins 3 and 11.
From the Reset Mode it can be commuted to any of the other modes and vice versa, but it is
not possible to commute between Modes 0, 1 and 2 without passing through Reset Mode
first.
5.2.3 Indications of the status LEDs
Situated in the main control board, on the front part shown in figure 21, the T3 has 3 LEDs that
indicate its present status.
Their functions and the information related to the signals that are emitted are described below.
Figure 21: Status LEDs
Power supply
The green LED indicates that the Hopper is ON. It remains activated whenever the hopper is
active.
Security
The green LED remains on whenever the hopper is active and there is no error. When there
is an error, the LED switches off (OFF).
Sensor
The red LED remains off (OFF) while the hopper is on standby. On each exit of a coin, the
LED flashes once. The LED indicates the Errors by flashing a number of times,
Error 1
: 1
Power
Security
Sensor