32
07 - 2009
Configuration by dipswitches
5.2.2 Working
modes
When the configuration of the working mode is carried out using the connection with the master
(Configuration by hardware), the Working mode is established in the connection of the hopper.
Mode 0 – Direct Mode
This mode is selected when, from the connection with the master, IN1 and IN2 stay open. On
applying the power supply to the motor, it starts, when this voltage is removed, the motor
stops.
Mode 1 – Negative Logic
In this mode, the power supply of the Logic and the voltage of 24V of the motor may be
permanently connected. The motor is controlled by means of a level logic on IN3.
When IN1 and IN2 receive 0V, Mode 1
is
selected. When the power supply is connected, the
motor starts by means of low level signal on IN3, a high level stops the motor.
Mode 2 – Pulse mode
Mode 2 is selected by means of hardware when IN1 is high and IN2 is low.
In this mode, the hopper carries out the payment of one coin for each pulse received from
IN3.
Reset Mode
This mode is used as a security mode. The hopper stops immediately when it is commuted to
this mode, independently of the operation mode it was commuted from.
Table 18: Parallel configuration modes
Figure 18: Details of the dipswitches on the
PCB