8
CONNECTION OF CAR PANELS
1.
For ALYA Series COP
a)
Connect cable labelled CON(A) between CON(A)
socket in RBC board and CONA socket of ALYA car
panel.
b)
If you have two COPs inside the cabin, then
connect CON(B) between RBC board and CON
socket of the second ALYA car panel in the cabin.
Set door type to B from ALYA car panel dip
switch.
2.
For other COP Series
a)
Connect cable labelled CON(A) between CON(A)
socket in RBC board and CON socket of PWS
board in car panel.
b)
If you have two COPs inside the cabin, then
connect CON(B) between RBC board and CON
socket of PWS board inside the second car panel
in the cabin. Set door type to B from PWS dip
switch.
See AP02-CAR OPERATING PANEL section in Appendix for
mechanical and electrical installation of car panels.
CONNECTIONS OF CAR CIRCUIT
Connect the remaining car devices to the inspection box as shown in the following circuit diagrams
presented in schemas of the project on pages:
C02-CAR TOP CONNECTIONS RBC.