5
CONNECTING LINE SUPPLY
Connect power line cables to the terminals
L1/R, L2/S, L3/T and N.
CONNECTING MOTOR POWER
1.
Connect motor power inputs to U, V, W
terminals in controller box.
2.
Use the given shielded motor cable for this.
3.
Connect shielding of the cable to the earth
bar in the controller.
CONNECTING BRAKING RESISTOR
1.
Fix the braking resistor on to the wall or
device.
2.
Do not put the resistor into the device.
3.
Be aware that it will be hot and will emit heat
to the surroundings during lift operation. Do
not touch it during operation.
4.
Connect the cables of the braking resistor to
the terminals P+, BR in control box.
5.
Connect the shielding of the cable to the
earth bar inside the control panel.
6.
Do not run the motor without connecting
the appropriate braking resistor. Otherwise
the device may be damaged.
RECALL COMMAND BOX
The recall command box is inside the device.