The following table illustrates the technical characteristics of all cables:
Cables
TYPE
SECTION
NOTES
Backup Supply
0.10-0.33
mm
2
/
26-22AWG
-
Motor Cable
-
It must be shielded and twisted.
It must have a capacity less than 150pF/m.
The Max cable length is up to 10m without filter.
Control signals
and
I/O signals
from PLC/CNC
0.10-0.33
mm
2
/
26-22AWG
see cap. 2.4 Note about cable shielding on page 27.
Encoder signals
(commutation)
0.10-0.33
mm
2
/
26-22AWG
It must be shielded.
It must have a capacity less than 120pF/m.
Encoder signals
(serial)
0.10-0.33
mm
2
/
26-22AWG
Capacitance 800 ÷ 1000Hz : ≤90pF/m
Characteristic Impedance at 10MHz : 110 ± 10 Ω
External resistor
1.5
mm
2
/15AWG
If the cable length is longer than 20/30cm, it must be
twisted and shielded. The shield must be connected to
ground on both ends, utilising U-clamps to the zinced
panel of the electrical box.
CanBus
communication
0.25
mm
2
/
0.34
mm
2
Cable capacitance: Max 60 nF/km.
Impedance characteristics : 100...120Ω.
Lead resistance (loop): 159,8 Ω/km.
The length depends upon the transmission speed:
• 1000kbit/s 20m Max;
• 500kbit/s 70m Max;
• 250kbit/s 115m Max.
SpeederOne.2
interface
-
Micro USB B 5P to USB A type male.
The cable length must be shielded and 3m Max.
Notes:
• Avoid crossing, overlapping and twisting cables together. If it is absolutely necessary to cross
them, do so at 90°.
• Use only copper conductors for cabling.
2.3 Cables characteristics