4.11 CanBus - Settings
The drive can be controlled in CanBus interface.
The procedure is the following:
1
- Perform the
basic installation procedure (
see cap. 2.5 Basic installation on page 28 )
;
2
- In the “
Settings
” window set:
a- Set the operative mode "
7: Can Open
".
b- The baud rate parameter to define the communication speed and so the performance of the system.
All drives connected to the network must have the same baud rate.
c- For each drive on the same network set a different "CanBus ID".
d- Save always in Eeprom to save the settings.
3
- Connect the first drive to the CAN MASTER by using a CanBus cable.
4
- Connect each drive to the preceding and the following by using a CanBus cable.
5
- Connect a RESISTOR (120 ohm, 1/4W) between pins CAN H and CAN L of the last drive of the network.
See "
CanOpen/Ethercat Reference Manual
" for a more detailed description about the CanOpen
protocol implemented on the drives (contact Axor).