113
AXOR Industries
Service Manual
NanoMack
®
ver.1 rev.11/'19
5.13 Oscilloscope
DATA ACQUISITION:
Single Acquisition
Selecting the
Single Acquisition
option, the oscilloscope's behaviour is dependant upon enablement/
disablement of a trigger event:
CASE 1
: If the trigger event is enabled on rising edge or falling one of signal in Channel 1, the
oscilloscope waits for the first trigger event. At trigger arrival the trace is visualized and data
acquisition is stopped. To capture a new trigger event it is necessary to start a new acquisition
by clicking on the icon
.
CASE 2
: If trigger event is disabled, the oscilloscope acquires new data, it visualizes it, then it
stops. To upgrade the trace it is necessary to start a new acquisition by clicking on the icon
.
Continuous Acquisition
Selecting the
Continuous Acquisition
option, the oscilloscope's behaviour depends upon enablement/
disablement of trigger event:
CASE 1:
If trigger event is enabled on the rising or falling edge of a signal in Channel 1, os-
cilloscope waits until the first trigger event. At trigger's arrival the trace is visualized and it is
updated at each trigger event.
CASE 2
: If trigger is disabled, oscilloscope continually acquires new data and updates traces.
It starts data acquisition
in both modes
Single
or
Continuous Acquisition.
It stops data acquisition
in Continuous
Acquisition mode, or in Single Acquisition
mode if there is not a trigger event.
START/STOP DATA ACQUISITION: