Connector X2 (available only in AXRES-CO-V2)
X2 is a 6 way spring loaded connector located on the PCB. It accepts wires up to AWG20
Pin
Signal
Type
Function
1
System GND
GND
System ground, sensor body
2
GND
GND
Power supply ground
3
CAN lo
CAN
CAN bus lo signal
4
CAN sh
CAN
CAN shield
5
CAN hi
CAN
CAN bus hi signal
6
V supply
PWR
Power supply
Table 5.5: Connector X2
Power supply voltage range is 9...35 V.
CAN bus signals withstand short circuits to 40V and GND
5.2
CAN bus cabling
The bus should be routed continuously from one module to another. A 120 ohms terminating
resistor must be attached to both ends of the bus. It is recommended to use at least 7W
resistors to ensure that they withstands short circuits to power supply lines.