DSP resolver user manual
User Manual
Version 1.15
3.
SUMMARY OF TECHNICAL SPECIFICATIONS
All specifications typical at nominal input voltage (24 V) and 25° C unless otherwise
specified.
Operating voltage
(power supply
requirement)
9 to 35 VDC for AXRES-CO-V2-1X-x
9 to 54 VDC AXRES-CO-1X-SL
Reverse polarity
protection
Provided
Current consumption
70mA with 24volts
RS232
Baudrates up to 115200 kbits/sec, TTL level in AXRES-CO-V2
CAN
Philips TJA1050 Transceiver
Baudrates 50kB to 1MB
Sensor element
AXRES-CO-V2:
•
1X: LTN R58WURE151B24-031-07HA
•
3X: LTN R58WURE153B24-031-07HA, on request
AXRES-CO-1X-SL
•
LTN RE-10
Measuring range of
angular rotation as
degrees
360°, with 1X sensor element
120°, with 3X sensor element. 3 uniform sectors in one 360 degrees mechanical
rotation
Accuracy
+-0,067° for 1X (12,5 bits)
+-0,028° for 3X (13,5 bits)
Resolution
0,01°, as default. SW adjustable.
Repeatibility
+-0.005 degrees (15 bits)
Noise in position
output
+-0.0025 degrees (16 bits)
Delay between
mechanical rotation
and sensor output
less than 28 ms
Table 3.1: Electrical Specifications
Copyright
©
Axiomatic Technologies Oy
8/56