DSP resolver user manual
User Manual
Version 1.15
index
h
su
b
obj.
variable
type
b
yt
es
acce
ss
M/
O
pd
o
profile value
Default
value
value range
notes
Bit 2
Output scaling, 0 = >disabled, 1 => enabled (sensor position
is scaled with units per revolution value and preset value is
added into it)
Bit 3
Not supported with rotary sensors
Bits 4 - 11
Reserved
Bit 12
Reserved for manufacturer specific use
Bits 13-15
Reserved for manufacturer specific use
6501
VAR
co_single_turn_resolution
U32
4
RO
M
n
36000
0x1-
0x400000
Tells the current resolution36000 if scaling is disabled. Otherwise
co_unit_per_revolution.
6502
VAR
co_number_of_distinguishab
le_revolutions
U16
2
RO
M
n
1
Maximum amount of measurable revolutions. (Revolution counter
counts revolutions from position during last reset. This position is not
absolute)
6509
VAR
co_offset_value
I32
4
RW
O
n
0
(-1
*co_single_tu
rn_resolution
+1) ...
(co_single_tu
rn_resolution
-1)
Offset value for position value manipulation
Copyright
©
Axiomatic Technologies Oy
56/56