live in Riga, Latvia, your offset will be +2 hours.
»
DST in effect (+1 hour):
In those area that im-
plement Daylight Savings Time, this check box
is used to tell your system to add one hour to the
GMT offset.
»
NTP:
The check box should be checked if your
DESQ’s NTP clock sync function is enabled.
To disable NTP service, simply un-check this
box. The other box here is used to enter the
IP address of your external NTP server. This
server may be a PC on your local network or
it may be the IP address of a public NTP serv-
er in the Internet. Note that you must speci-
fy an IP address – a URL will not work.
If you wish to connect to a public or external
NTP server, be sure to specify a valid Gateway
in your IP configuration.
•
Configuration:
This is an extremely important area
of your QOR configuration since this is where you
will backup all of the hard work you have done.
»
Backup Settings:
All QOR settings can be saved
in a single operation and backed up to a location
on your local drive. When you select the
Backup
option, you will see the familiar location navigator
that prompts you for the folder in which you wish
to store your backup file. The backup file will be
named according to the device name, IP address
and date/time the backup was performed. This
naming conventions allows you to store multiple
backups from multiple devices in the same loca-
tion. An example of a backup file name might be
QOR-192.168.0.200-2012-03-25_17-13.xml.
»
Restore Settings:
To restore a previous QOR
backup, use the browse button to locate the back-
up and then select
Restore.
log, log History and log Setup Menus
QOR keeps a detailed log of user actions and other
system events. Choosing the
Log
menu item lets you ex-
amine the last 100 logged activities; choosing the
Log
History
menu item allows you to view an entire day’s
log at one time and delete old log files if you choose.
The oldest log files are deleted automatically as storage
space dictates.
The
Log Setup
menu item allows you to specify an
external Syslog server and to configure the debug level.
This menu also allows you to specify from eight differ-
ent severity level filters. The filter choices (in order of
decreasing severity) are:
•
Emergency: system us unusable
• Alert: action must be taken immediately
•
Critical: critical condition
•
Error: error conditions
• Warning: warning conditions
•
Notice: normal but significant condition
•
Informational: informational messages
•
Debug: debug level messages
Use this section as directed to do so by Tech Support.
the Module Manager
The
Module Manager
heading displays informa-
tion about the control surfaces connected to your QOR.
Some of these fields are for diagnostics; below is a list of
those you might find useful:
»
Address:
displays the number Axia has assigned
to each connected unit.
»
Type:
gives you the working name of the module.
»
State:
tells you whether or not the module is
working, i.e., communicating with the CPU.
»
Ping
: Indicated ping response in ms.
Figure 6-3: Customize Screen
Содержание DESQ
Страница 1: ...RAQ DESQ Installation User s Guide Manual Rev 1 January 2012 p n 1490 00086 001...
Страница 8: ...Introduction viii 2012 Axia Audio...
Страница 10: ...Introduction x 2012 Axia Audio Crimping the spade lugs the smell of soldering flux they ll be missed Not much...
Страница 12: ...Getting Started 2 2012 Axia Audio Open box connect Seven pounds of pure power Who needs big consoles...
Страница 30: ...2 Inputs and Outputs 20 2012 Axia Audio CAT 6 small and light yet sound and data pour forth What magic is this...
Страница 61: ...6 Advanced Controls 51 2012 Axia Audio Mimicking nature streams combine to form anew many become one...
Страница 80: ...Axia Audio a Telos Alliance Company 1241 Superior Ave Cleveland Ohio 44114 USA 1 216 241 7225 www AxiaAudio com...