AW86225
October 2021 V1.9
www.awinic.com
5 Copyright © 2020 SHANGHAI AWINIC TECHNOLOGY CO., LTD
Absolute Maximum Ratings
(NOTE 1)
PARAMETERS
RANGE
Supply voltage range VDD
-0.3V to 6.0V
HDP, HDN, TRIG/INTN
-0.3V to VDD+0.3V
SDA, SCL, RSTN
-0.3V to 6.0V
Minimum load resistance R
L
5Ω
Junction-to-ambient thermal resistance
a
132°C/W
Operating free-air temperature range
-40°C to 85°C
Maximum Junction Temperature
T
JMAX
150°C
Storage Temperature Range
T
STG
-65°C to 150°C
Lead Temperature(Soldering 10 Seconds)
260°C
ESD(Including CDM)
(NOTE 2 3)
HBM(Human Body Model)
±2KV
CDM(Charge Device Model)
±1.5KV
Latch-up
Test Condition
: JEDEC EIA/JESD78E
+IT: 200mA
-IT: -200mA
NOTE 1
:
Conditions out of those ranges listed in "absolute maximum ratings" may cause permanent
damages to the device. In spite of the limits above, functional operation conditions of the device should
within the ranges listed in "recommended operating conditions". Exposure to absolute-maximum-rated
conditions for prolonged periods may affect device reliability.
NOTE 2
:
The human body model is a 100pF capacitor discharged through a 1.5kΩ resistor into each pin.
Test method: ANSI/ESDA/JEDEC JS-001-2017.
NOTE 3
:
Charge Device Model test method: ANSI/ESDA/JEDEC JS-002-2018.
awinic Confidential