Measurement Setup
AW86225 features switching digital output, as shown in Figure 6. Need to connect a low pass filter to HDP/HDN
output respectively to filter out switch modulation frequency, then measure the differential output of filter to
obtain analog output signal.
HDP
HDN
AW86225
3.4kHz
Low-Pass Fliter
100k
Ω
100k
Ω
0.47nF
0.47nF
LRA
Figure 6 AW86225 test setup