7 Maintenance
M
Spray head, rotating TYPE A, B, C, or D / alternative static spray head type S on TANKO-RTS
anti-twist version
N
Hydraulic pipe for holding the spray head
P
Power cylinder, pneumatic actuator with 3 limit switches
R
Central bearing
S
T
Power cylinder
Resistance Thermometer
WARNING
Risk of the device falling accidentally!
The device may hit personnel when falling.
There is a risk of severe physical injury.
Hold the device firmly when installing/removing it.
There must be nobody beneath the device when installing/removing it.
NOTE
During removal, the device should be in the rest position, i.e. with the spray head retracted into
the hydraulic pipe to create a seal. If this is not possible due to a fault, the spray head will protrude into
the container.
The small installation opening for the container and components (e.g. agitators) in the container cause
obstructive contours! The spray head may collide with obstructions during removal.
Damage to the device.
The spray head must NOT collide with obstructive contours!
Interfaces F, G and T
NOTE
The limit switch and the resistance thermometer are electrical components. The electrical
connection values are not included in these instructions; they must be obtained from the
instructions/data sheet provided by the sensor manufacturer.
The limit switches and the resistance thermometer may be damaged if connected incorrectly or
subjected to excessive voltage.
Follow the manufacturer instructions for the limit switch and resistance thermometer!
1.
Check and ensure that the power supply to the limit switches and to the resistance thermometer is
switched off (see
Section 7.3 Switch-Off
.
2.
Disconnect the electrical power supply from the limit switches and the resistance thermometer, or
3.
remove the limit switches and the resistance thermometer from the retractor system.
(See installation instructions/data sheet provided by manufacturer).
Interfaces D and E
1.
Check to ensure that the compressed air supply is interrupted (see
Section 7.3 Switch-Off
2.
Detach the compressed air hoses from the screw connections on the device
3.
Unscrew the throttle check valve position E.