ATEX Retractor System TANKO-RT/-RTS
3 Design and Function
Translation - Operating/installation instructions 2020/01
39/121
Technical Data for Hydraulic Side
Designation
TANKO-RT/RTS
Range
see
Operating temperature (permitted):
–
Cleaning medium
+5 °C (+41 °F) to +95 °C (+203 °F)
There is no potentially explosive mixture in the container during
cleaning. The cleaning medium must not even result in the
development of potentially explosive mixtures during spraying.
+5 °C (+41 °F) to +60 °C (+140 °F)
There is a potentially explosive atmosphere in the container
during cleaning and the cleaning medium is not flammable.
+5 °C (+41 °F) to flash point T
flash point
-15 °C (max. 60 °C)
There is a potentially explosive atmosphere in the container
during cleaning and the cleaning medium is flammable and a
flash point can be verified for this material.
Ambient temperature (permitted):
In the container to be cleaned
–
During the cleaning process
+5 °C (+41 °F) to +95 °C (+203 °F)
There is no potentially explosive mixture in the container during
cleaning. The cleaning medium must not even result in the
development of potentially explosive mixtures during spraying.
+5 °C (+41 °F) to +60 °C (+140 °F)
There is a potentially explosive atmosphere in the container
during cleaning.
–
Idle state
O-Ring material EPDM
O-Ring material FKM and FFKM
-20 °C (-4 °F) to +130 °C (+266 °F)
-15 °C (+5 °F) to +140 °C (+284 °F)
Operating pressure, cleaning
medium
–
Liquid medium
–
Gaseous medium (air or nitrogen)
< 1 – 6 bar (14.5 – 87 psi g) recommended 3 bar (43.5 psi g)
1 bar (14.5 psi g), max. 1 min
0.5 bar (7.25 psi g), max. 2 min
Volume flow rate (depending on
spray head type)
see
Rotation speed:
–
with water
–
with air
500 – 2,000 rpm
900 – 2,000 rpm
Process connection [PC]:
see
Media connection [MC]:
Clamp DN25, DIN 32676
Adapter on clamp connection 1" series C DIN 32676 possible.
Table 3.3-3: Operating Parameter, Hydraulic Side