![Avaya Secure Router 2330 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/avaya/secure-router-2330/secure-router-2330_hardware-installation_3027991046.webp)
Figure 25: 1-port ADSL2+ Annex B Small Module
The following table lists the connectors and cables to use with the 1-port ADSL2+ Small
Modules.
Table 30: Cables and connectors
Port
Connector
Recommended
cable type
Minimum cable
length
Loop length
ADSL2
+
RJ11
24 AWG Category 5
twisted pair cable
—
17000 ft (5180 m)
Important:
Ensure that you use straight cables with ADSL2+ modules. The TIP must connect to TIP
and RING must connect to RING.
The following table describes the LED status for the 1-port ADSL2+ Small Modules.
Table 31: Module LEDs
LED
Description
STAT
Status of general module:
• Off—No power available to the module.
• Yellow—Out of service, or failed to initiate.
• Green—Power on and the module is operational.
LINK/STAT 1
Status of interface 1
• Off—Not connected or the interface is out of service.
• Yellow—The interface is in a loopback mode or is running
diagnostics.
• Green—The link or channel is active and receiving a valid signal.
Avaya Secure Router 2330/4134 hardware components fundamentals
46 Installation — Hardware Components
August 2013
Содержание Secure Router 2330
Страница 4: ...4 Installation Hardware Components August 2013 Comments infodev avaya com...
Страница 8: ...8 Installation Hardware Components August 2013...
Страница 18: ...New in this release 18 Installation Hardware Components August 2013 Comments infodev avaya com...
Страница 104: ...104 Installation Hardware Components August 2013 Comments infodev avaya com...
Страница 120: ...120 Installation Hardware Components August 2013 Comments infodev avaya com...