Data modules and asynchronous data units
555-233-116
94
Issue 4 October 2002
Proceed as follows.
1. Calculate an option-selection value using
Table 12
,
‘‘Codes for disabling
default settings of the 8400B data module’’
. Add up the disabling codes for
all options that you wish to disable.
For example, if you turned off With Telephone, US Companding, Disable
Data Metering Feature, the selection code would be:
1 + 2 + 16 = 19
2. Check the current data-module setting by entering ATS24?.
3. If the current value does not match the selection value you calculated,
enter ATS24=nnn, where nnn is the selection value you calculated.
Configuring the ExpressRoute 1000 data module
You can substitute an ExpressRoute 1000 data module for the 8400B data
module. Both DCP and ISDN-BRI connections are possible.
Figure 18
shows
typical connections.
!
CAUTION:
In DC-powered cabinet installations, a 105C Isolator adapter is required
when connecting equipment to a data module.
Disable Data Metering Feature
16
Immediate Speakerphone Activation
32
Automatic Speakerphone Activation
64
Disable Busyout During Local Loopback Test
128
Table 12.
Codes for disabling default settings of the 8400B data module
Default setting
Disabling code
Continued on next page
Содержание MultiVantage
Страница 6: ......
Страница 14: ...Contents 555 233 116 14 Issue 4 October 2002 A Connector and cable pinout charts 231 IN Index 243...
Страница 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Страница 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Страница 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Страница 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Страница 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Страница 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Страница 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Страница 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Страница 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Страница 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...