Installing and administering the terminal server
Issue 4 October 2002
123
555-233-116
Cabling diagram
Figure 22
shows the connection between the terminal server port and a call
accounting system.
Figure 22.
Stand-alone call accounting system link using a terminal server
Making the connections
Connect the adjunct to the IOLAN+, using the RJ45-to-DB25 cable and the null
modem. You can use a male/female adapter. See
Figure 23
.
Figure 23.
Connecting an adjunct to the IOLAN+
1. C-LAN circuit pack, or IP connection on
an S8300/G700
2. Local area network (LAN)
3. IOLAN+ 104 terminal server
4. Adjunct (system management terminal
or a system printer, for example)
5. Null modem
6. PC or laptop (for initial administration)
7. DB25-to-RJ45 cable
8. DB25-to-DB9 cable
clan2gca.cdr
50 Ft. Maximum
Standalone
Call Accounting
Call
Accounting
Port
Demarcation
Point
M25A or M25B
RS232 Cable
«
C-LAN
Switch
Hub or
Router
328 ft max
(100 m)
328 ft max
(100 m)
AC Power
Terminal Server
RJ45 Cat 5
Modular Cord
RJ45 Cat 5
Modular Cord
259A Adapter,
356A Adapter (Jack #1), or
258B Adapter (Jack #1)
cydfrcon KLC 021201
1
2
4
DATA CONNECTIONS ONLY - NOT FOR TELECOM USE
1
2
3
4
10BASE-T
5VDC
3
7
7
8
5
5
6
Содержание MultiVantage
Страница 6: ......
Страница 14: ...Contents 555 233 116 14 Issue 4 October 2002 A Connector and cable pinout charts 231 IN Index 243...
Страница 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Страница 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Страница 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Страница 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Страница 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Страница 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Страница 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Страница 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Страница 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Страница 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...