Set clock options
Issue 4 October 2002
167
555-233-116
Stratum 3 clock wiring installation procedure
1. Connect the B25A cables from the TN780 connector panel slot on the
system cabinet and the Stratum 3 Clock to the cross-connect module in the
yellow field.
2. Connect the CSU plug end of the H-600-274 Y-cable to the primary CSU.
Route an H600-307 cable from the DS1 connector panel slot on the system
cabinet to the connector on the “SYSTEM” end of the Y-cable.
3. Route a B25A cable from the “CLOCK” end of the Y-cable to the cross-
connect module in the yellow field.
4. Repeat steps 2 and 3 for the secondary CSU. The maximum allowable
cabling distance between the Stratum 3 clock and the CSU is shown in the
table below.
5. For standard reliability systems, refer to Y-cable to cross-connect the
TN780 and “CLOCK” end connections to the Stratum 3 clock connections
on the cross-connect module.
6. For high or critical reliability systems, refer to table below to cross-connect
the TN780 and “CLOCK” end connections to the Stratum 3 clock
connections on the cross-connect module.
Table 19.
Maximum cabling distance for different CSUs
Channel Service Unit (CSU)
Maximum Cabling Distance
551A
85 feet (27 m)
551V
85 feet (27 m)
551V EFS/R
755 feet (199.7 m)
EFS T1
755 feet (199.7 m)
Table 20.
Y-cable clock-end cross-connects for reliability
From Stratum 3 Clock
To Y-cable clock end
(primary)
To Y-cable clock end
(secondary)
Lead
Name
Lead Color/
Terminal
Lead
Name
Lead Color/
Terminal
Lead
Name
Lead Color/
Terminal
RREF1
W-BL/1
V-O/43
TREF1
BL-W/2
O-V/44
RREF2
W-O/3
V-O/43
TREF2
O-W/4
O-V/44
Содержание MultiVantage
Страница 6: ......
Страница 14: ...Contents 555 233 116 14 Issue 4 October 2002 A Connector and cable pinout charts 231 IN Index 243...
Страница 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Страница 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Страница 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Страница 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Страница 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Страница 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Страница 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Страница 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Страница 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Страница 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...