Terminal server installation
555-233-116
122
Issue 4 October 2002
Installing and administering the
terminal server
Make sure you have all the equipment on site before the installation. You must
have the hardware listed in
Table 14
.
You also need a computer (laptop) with the HyperTerminal software program for
the initial administration of the IOLAN+ and to set up the ports.
The general process is to
■
Connect the IOLAN+ to the adjunct and the LAN
■
Administer the ports on the IOLAN+ using a PC or laptop at the local site
■
Test the connectivity back through the switch
Distance limits
The distance limit from the switch to the LAN hub is 328 feet (100 meters). The
distance limit from the LAN hub to the terminal server is 328 feet (100 meters). If
installed, the limit from the terminal server to the adjunct is 50 feet (15 meters).
Table 14.
Required equipment
Comcode
Description
Qty
Supplier
700015084
IOLAN+ 104 communications server
1
Avaya
NA
RJ45-to-DB25 connector for IOLAN+
(supplied with 700015084)
4
Avaya
NA
DB25-to-DB9 connector for PC COM port
1
Avaya
NA
RS232 Null modem (if needed for PC or
printer connectivity)
1 or more
Avaya
405369042
Male/female adapter (if necessary)
1 or more
Avaya
846943306
or 104154414
NA
6-inch RJ45 crossover cord, or
10/100Base-T auto-sensing LAN hub or
router
1
1
Avaya
Customer
102631413
NA
259A adapter, or
CAT5 cross connect hardware and
connecting blocks
1
Avaya
Customer
NA
RJ45 UTP Category 5 modular cords
1–2
Customer
NA
451A in-line RJ45 adapters, as needed to
connect modular cords together
Содержание MultiVantage
Страница 6: ......
Страница 14: ...Contents 555 233 116 14 Issue 4 October 2002 A Connector and cable pinout charts 231 IN Index 243...
Страница 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Страница 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Страница 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Страница 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Страница 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Страница 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Страница 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Страница 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Страница 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Страница 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...