Administering the loopback jack
Issue 4 October 2002
137
555-233-116
Administering the loopback jack
1. At the management terminal, enter change ds1 location, where location
is the DS1 interface circuit pack corresponding to the loopback jack.
2. Be sure the near-end CSU type is set to integrated.
3. On page 2 of the form, change the supply CPE loopback jack power
field to y.
Setting this field to y informs the technician that a loopback jack is present
on the facility and allows the technician to determine that the facility is
available for remote testing.
4. Enter save translation to save the new information.
Loopback testing with a smart jack
The loopback jack and smart jack isolate faults by dividing the DS1 span into 3
sections (see
Figure 24
, through
Figure 29
):
■
From the 120A2 (or later) ICSU, or from the MM710, to the loopback jack
■
From the loopback jack to the smart jack (network interface point)
■
From the smart jack to the CO
The first 2 sections are your responsibility. The last is the responsibility of the DS1
service provider.
Testing the DS1 span from the ICSU to the
loopback jack
The DS1 span test has 2 parts.
■
Checking for circuit connectivity
The first part of the test powers-up the loopback jack and sends a signal
from the DS1 circuit pack, through the wiring, to the loopback jack. The test
allows about 10 seconds for the signal to loop around the loopback jack
and return to the DS1 circuit pack. Then it sends the results to the
management terminal and proceeds to the second part of the test.
■
The second part of the test sends the standard, 3-in-24 DS1 stress-testing
pattern from the DS1 board, through the loopback jack, and back to a bit
error detector and counter on the DS1 board. A bit-error rate counter
displays the results on the management terminal until you terminates the
test.
Always perform both parts of the test. Proceed as follows.
Содержание MultiVantage
Страница 6: ......
Страница 14: ...Contents 555 233 116 14 Issue 4 October 2002 A Connector and cable pinout charts 231 IN Index 243...
Страница 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Страница 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Страница 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Страница 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Страница 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Страница 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Страница 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Страница 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Страница 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Страница 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...