Post-upgrade tasks
Issue 7 January 2005
365
To busy out trunks
1. Busy out trunks that were busied out before the upgrade (see
To record all busyouts
on
page 328).
To check for translation corruption
1. Type
newterm
and press Enter.
If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing the
upgrade.
To resolve alarms
1. On the Maintenance Web Interface, under Alarms click Current Alarms to examine the
alarm log.
2. If any alarms are listed, click Clear All.
3. Resolve new alarms since the upgrade through Communication Manager using the
appropriate maintenance book.
To re-enable alarm origination
1. Telnet to the S8300 and log on.
2. At the command prompt, type
almenable -d b -s y
,
where
-d b
sets the dialout option to
both (numbers)
-s y
enables SNMP alarm origination
3. Type
almenable
(without any options) to verify alarm origination enabled status.
To back up the system
1. Using the Maintenance Web Interface, back up the system as you did before the upgrade
selecting Save Translations and all backup sets.
To restart LSPs (if any)
To restart Communication Manager on an LSP after the upgrade:
1. Open a Telnet session on the S8300 (LSP).
2. At the command line, type
start -ac
and press Enter.
This completes the upgrade process for a G700 with an S8300.