![Avaya G700 Скачать руководство пользователя страница 315](http://html1.mh-extra.com/html/avaya/g700/g700_installation-manual_3027022315.webp)
Post-upgrade tasks
Issue 7 January 2005
315
To busy out trunks
1. Busy out trunks that were busied out before the upgrade (see
Pre-Upgrade Tasks — If the
S8300 is the primary controller
on page 252).
To check for translation corruption
1. Type
newterm
and press Enter.
If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing the
upgrade.
To resolve alarms
1. On the Maintenance Web Interface, under Alarms click Current Alarms to examine the
alarm log.
2. If any alarms are listed, click Clear All.
3. Resolve new alarms since the upgrade through Communication Manager using the
appropriate maintenance reference.
To re-enable alarm origination
1. Telnet to the S8300 and log on.
2. At the command prompt, type
almenable -d b -s y
where
-d b
sets the dialout option to
both (numbers)
-s y
enables SNMP alarm origination
3. Type
almenable
(without any options) to verify the alarm origination status.
To back up the system
Using the Maintenance Web Interface, back up the system as you did before the upgrade
selecting Save Translations and all backup sets.
To restart LSPs (if any)
To restart Communication Manager on LSPs (if any) after the upgrade:
1. Open a Telnet session on the S8300 (LSP).
2. At the command prompt, type
start -ac
and press Enter.
This completes the upgrade process for a G700 with an S8300.