28
500 Series
Battery disconnect switch
The loader is equipped with a
battery disconnect switch. The
switch is located in the rear of
the machine, on the right side
(see picture). Always switch off
main current when you leave the
loader unattended, and before
you do any maintenance or inspections. Switching the
battery disconnect switch to position OFF (horizontal
position of the switch key) will isolate the battery from the
electric system of loader, and will prevent hazards related
to damaged electric wires, short-circuit, and overheat of
electric components.
Risk of fire - Always switch off main
current when the loader is not used.
Turn the battery disconnect switch to
position OFF whenever leaving the
loader unattended or before servicing
the machine. If left on, there is a risk
of sparks and short-circuit during
maintenance and if any electric
insulator is faulty.
Controls in the footwell
Following picture shows the controls located in the footwell
1. Drive pedal, left:
drive backward
2. Drive pedal, right:
drive forward
See correct operation of the drive pedals on page 37.
Installing of service support
The red service support of the
boom lift cylinder is located at
the tip of the boom, behind the
attachment coupling plate.
Make sure that the boom
stays up during maintenance
operations by attaching the
service support on the lift
cylinder piston rod. Secure the
service support by locking it
on the piston rod with the long
screw that is on the support.
Risk of crushing - Always secure
the boom service support on the
boom lift cylinder before going
under the boom or any attachment.
Always secure the loader boom with
the provided service support, before
going under the loader boom. Remove
any load and attachments from the
loader before service or maintenance.
Operating instructions
WARNING
WARNING
Содержание 500 Series 2019
Страница 63: ... 63 500 Series Notes ...