GS1 Series AC Drive User Manual
4–13
Chapter 4: AC Drive Parameters
Decel S-Curve
Mem Addr 0104H(40261)
Range: 0 to 07
Default Setting: 0
This parameter is used whenever the motor and load need to be decelerated more
smoothly. The Decel S-Curve may be set from 0 to 7 to select the desired
deceleration S-Curve.
Note: From the diagram shown below, the original setting accel/decel time will be
for reference when the function of the S-curve is enabled. The actual accel/decel
time will be determined based on the S-curve selected (1 to 7).
Acceleration Time 2
Mem Addr 0105H(40262)
Range: 0.1 to 600.0 sec
Default Setting: 10.0
•The Second Acceleration Time determines the time for the AC drive to accelerate
from 0 RPM to Maximum Motor RPM (0-04). Acceleration Time 2 (1-05) can be
selected using a multi-function input terminal or frequency transition (1-07).
Deceleration Time 2
Mem Addr 0106H(40263)
Range: 0.1 to 600.0 sec
Default Setting: 30 sec
•The Second Deceleration Time determines the time for the AC drive to decelerate
from Maximum Motor RPM (0-04) to 0 RPM. Deceleration Time 2 (1-06) can be
selected using a multi-function input terminal or frequency transition (1-07).
1-06
1-05
1-04
Time
Disabling S curve is disabled in (1), (2)
1-03 sets S curve for (3)
1-04 sets S curve for (4)
(4)
(3)
(4)
(3)
(2)
(1)
(2)
(1)
1-03
1-04
Frequency
Содержание GS1-10P2