Chapter 3: Keypad Operation and Quickstart
GS1 Series AC Drive User Manual
3–8
Source of Frequency Command
Setting: 2
The frequency of the AC drive will be determined by an external potentiometer
with a 0 to +10V signal.
Default: 0
Settings:
0
Frequency determined by keypad potentiometer
1
Frequency determined by digital keypad up/down
2
Frequency determined by 0 to +10V input on AI
terminal. AI switch must be set to “V”.
3
Frequency determined by 4 to 20mA input on AI
terminal. AI switch must be set to “I”.
4
Frequency determined by 0 to 20mA input on AI
terminal. AI switch must be set to “I”.
5
Frequency determined by RS485 communication
interface
User Defined Display Function
Setting: 1
The AC drive display will default to motor speed (RPM) when running.
Default Setting: 0
Settings:
0
Output Frequency (Hz)
1
Motor Speed (RPM)
2
Output Frequency x 8-01
3
Output Current (A)
4
Motor Output Current (%)
5 Output
Voltage(V)
6 DC
Bus
Voltage
(V)
9
Frequency Setpoint
8-00
4-00
Switch must be set to
“V” in order to use a 0
to +10V input
Switch must be set to
“I” in order to use a 4
to 20mA input
Switch must be set to
“I” in order to use a 0
to 20mA input