Rung 16 loads a decimal value of 600 into drive parameter 9-26. The BIN instruction
converts BCD/HEX to decimal. This tells the drive to run at 60.0Hz.
Rung 17 sets the motion of the drive to forward by loading a value of 0 into
parameter 9-28. V2021 is the 18th V-memory register in the block of 20 that is
being written to in the WX instruction in Rung 5.
Rung 18 sets the motion of the drive to reverse by loading a value of 1 into parameter
9-28. V2021 is the 18th V-memory register in the block of 20 that is being written
to in the WX instruction in Rung 5.
GS1 Series AC Drive User Manual
5–15
Chapter 5: GS1 MODBUS Communications
X4
K600
LD
BIN
V2017
OUT
16
X6
K0
LD
17
V2021
OUT
(
)
END
19
(
)
NOP
20
X7
K1
LD
18
V2021
OUT
Содержание GS1-10P2