H2-CTRIO(2) Specifications
CTR
IN
OK
ER
1A
2A
0
1
2
3
H2-CTRIO
+24 VDC
OUTPUTS
2A
2B
2C
2D
2M
C2
Y2
C3
Y3
1A
1B
1C
1D
1M
NC
C0
Y0
C1
Y1
IN 9-30 VDC 5-12 mA
OUT 5-36 VDC
1.0Amax
per point
CTR
IN
OK
ER
1A
2A
0
1
2
3
H2-CTRIO2
+24 VDC
OUTPUTS
2A
2B
2C
2D
2M
C2
Y2
C3
Y3
1A
1B
1C
1D
1M
NC
C0
Y0
C1
Y1
IN 9-30 VDC 5-12 mA
OUT 5-36 VDC
1.0Amax
per point
Input Specifications
Specifications
H2-CTRIO*
H2-CTRIO2
Inputs
8 pts sink/source
Maximum Input Frequency
100kHz
250kHz
Minimum Pulse Width
5µsec
0.5 µs
Input Voltage Range
9–30 VDC
9–30 VDC
Maximum Voltage
30VDC
Input Voltage Protection
Zener Clamped at 33VDC
Rated Input Current
8mA typical 12mA maximum
Minimum ON Voltage
9.0 VDC
Maximum OFF Voltage
2.0 VDC
Minimum ON Current
5.0 mA
Maximum OFF Current
2.0 mA
OFF to ON Response
less than 3µs
less than 0.5 µs
ON to OFF Response
less than 3µs
less than 0.5 µs
Output Specifications
Specifications
H2-CTRIO*
H2-CTRIO2
Outputs
4 pts (sink/source), independently isolated
Pulse Outputs
2 channels, 20Hz to 25kHz Pulse/
Direction or CW/CCW
2 channels, 20Hz to 250kHz Pulse/
Direction or CW/CCW
Minimum Pulse Width
5µs
0.5 µs
Output Voltage Range
5–36 VDC
Maximum Output Voltage
36VDC
Maximum Load Current
1.0 A
1.0 A at 23°C
0.5 A at 60°C
Maximum Leakage Current
100µA
Inrush Current
5.0 A for 20ms
2.0 A for 10ms
ON State V Drop
0.3 VDC or less
0.45 VDC or less
Overcurrent Protection
Yes
OFF to ON Response
less than 3µs
less than 1µs
ON to OFF Response
less than 3µs
less than 1µs
General Specifications
Specifications
H2-CTRIO*
H2-CTRIO2
Discrete I/O Points Used
None (I/O map directly in H2-DM1/E data structure)
Base Power Required
400mA Max
275mA Max
Isolation
2500V I/O to Logic, 1000V among Input
Channels and All Outputs
1500V I/O to Logic, 1000V among Input
Channels and All Outputs
* The H2-CTRIO module has been discontinued. The H2-CTRIO2 is the replacement.