57
Figure 9-13
Sample Waveform Graph Mode Screen
1.
Settings Button (SetY)
—
sets the minimum and maximum values of the Y axis.
2.
Scale Button
—
changes the scale values.
There are two scale buttons displaying above the waveform graph to the right side,
which can be used to change the scale values of the X axis and Y axis of the graph.
There are four scales available for the X axis: x1, x2, x4 and x8, and three scales
available for the Y axis: x1, x2, and x4.
3.
Edit Button
—
edits the waveform color and the line thickness.
4.
Zoom-in Button
—
tap to display the selected data graph in full screen.
5.
Exit Button
—
tap to exit the waveform graph mode.
Full Screen Display
—
this option is only available in the waveform graph mode,
and mostly used in Graph Merge status for data comparison. There are four control
buttons available on the top-right side of the screen under this mode.
Scale Button
—
tap to change the scale values below the waveform graph.
There are four scales available for the X axis: x1, x2, x4 and x, and three scales
available for the Y axis: x1, x2, and x4.
Edit Button
—
tap to open an edit window, in which you can set the waveform
color and the line thickness displayed for the selected parameter.
Zoom-out Button
—
tap to exit full screen mode.
Exit Button
—
tap to exit the waveform graph mode.
To edit the waveform color and line thickness in a data graph
:
1.
Select parameters to display in Waveform Graph mode.
2.
Tap the
Edit
Button, and an edit window will display.