Test Mode
[Test_Call_TestMo
de]
Defines the test session mode.
[0]
Once = (Default) The test runs until the lowest value between the
following is reached:
Maximum channels is reached for the test session, configured by
'Maximum Channels for Session'.
Call duration ('Call Duration') multiplied by calls per second ('Calls
per Second').
Test duration expires, configured by 'Test Duration'.
[1]
Continuous = The test runs until the configured test duration is
reached. If it reaches the maximum channels configured for the test
session (in the 'Maximum Channels for Session'), it waits until the
configured call duration of a currently established tested call expires
before making the next test call. In this way, the test session stays within
the configured maximum channels.
Note:
This parameter is applicable only if 'Call Party' is set to
Caller
.
Test Duration
[Test_Call_TestDur
ation]
Defines the test duration (in minutes).
The valid value is 0 to 100000. The default is 0 (i.e., unlimited).
Note:
This parameter is applicable only if 'Call Party' is set to
Caller
.
Play
[Test_Call_Play]
Enables playing a user-defined DTMF signal to the answered side of the
call.
[0]
Disable (default)
[1]
DTMF
To configure the played DTMF signal, see 'Configuring DTMF Tones for
Test Calls' on page
Notes:
To configure the DTMF signaling type (e.g., out-of-band or in-band) use
the 'DTMF Transport Type' parameter (see 'Configuring DTMF Transport
Types' on page
This parameter is applicable only if 'Call Party' is set to
Caller
.
Schedule Interval
[Test_Call_Schedul
eInterval]
Defines the interval (in minutes) between automatic outgoing test calls.
The valid value range is 0 to 100000. The default is 0 (i.e., scheduling is
disabled).
Note:
This parameter is applicable only if 'Call Party' is set to
Caller
.
51.1.1 Starting, Stopping and Restarting Test Calls
The procedure below describes how to start, stop, and restart test calls.
To start, stop, and restart a test call:
1.
In the Test Call table, select the required test call entry; the
Actions
button appears
above the table.
2.
From the
Actions
drop-down list, choose the required command:
•
Dial
: starts the test call (this action is applicable only if the test call party is the
caller).
•
Drop Call
: stops the test call.
•
Restart
: ends all established calls and then starts the test call session again.
Содержание Mediant 3000
Страница 1: ...User s Manual Version 6 6 Enterprise Session Border Controller VoIP Digital Media Gateway Mediant 3000...
Страница 2: ......
Страница 21: ...Version 6 6 21 Mediant 3000 User s Manual 1 Overview Figure 1 2 Mediant 3000 TP 6310 Functional Block Diagram...
Страница 22: ...User s Manual 22 Document LTRT 89729 Mediant 3000 Figure 1 3 Mediant 3000 TP 8410 Functional Block Diagram...
Страница 26: ...User s Manual 26 Document LTRT 89729 Mediant 3000 Reader s Note...
Страница 27: ...Part I Getting Started with Initial Connectivity...
Страница 28: ......
Страница 40: ...User s Manual 40 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 41: ...Part II Management Tools...
Страница 42: ......
Страница 44: ...User s Manual 44 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 80: ...User s Manual 80 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 98: ...User s Manual 98 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 103: ...Part III General System Settings...
Страница 104: ......
Страница 113: ...Part IV General VoIP Configuration...
Страница 114: ......
Страница 144: ...User s Manual 144 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 164: ...User s Manual 164 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 222: ...User s Manual 222 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 224: ...User s Manual 224 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 275: ...Part V Gateway and IP to IP Application...
Страница 276: ......
Страница 278: ...User s Manual 278 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 399: ...Part VI Session Border Controller Application...
Страница 400: ......
Страница 402: ...User s Manual 402 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 464: ...User s Manual 464 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 465: ...Part VII Stand Alone Survivability Application...
Страница 466: ......
Страница 474: ...User s Manual 474 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 494: ...User s Manual 494 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 497: ...Part VIII IP Media Capabilities...
Страница 498: ......
Страница 501: ...Part IX High Availability System...
Страница 502: ......
Страница 515: ...Part X Maintenance...
Страница 516: ......
Страница 522: ...User s Manual 522 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 524: ...User s Manual 524 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 552: ...User s Manual 552 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 562: ...User s Manual 562 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 565: ...Part XI Status Performance Monitoring and Reporting...
Страница 566: ......
Страница 578: ...User s Manual 578 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 609: ...Part XII Diagnostics...
Страница 610: ......
Страница 624: ...User s Manual 624 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 626: ...User s Manual 626 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 638: ...User s Manual 638 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 639: ...Part XIII Appendix...
Страница 640: ......
Страница 864: ...User s Manual 864 Document LTRT 89729 Mediant 3000 Reader s Notes...
Страница 871: ...Version 6 6 871 Mediant 3000 User s Manual 55 Selected Technical Specifications Reader s Notes...
Страница 872: ...User s Manual Ver 6 6 www audiocodes com...