EMS Alarm Guide
60
Document #: 94602
EMS
Table 3-32: HA System Fault Alarm
Description
Originated when:
HA feature is active but the system is NOT working in HA mode.
Reason is specified (for example: SW WD exception error, HW WD
exception error, SAT device is missing, SAT device error, DSP error,
BIT tests error, etc).
HA feature is active and the redundant module is in start up mode but
hasn’t connected yet
HA system is active
SNMP Alarm
acHASystemFaultAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.33
Alarm Title
HA System Fault Alarm
Alarm Source
System#0/Module#<m> where m is the 6310 module’s slot number
Alarm Type
Quality Of Service Alarm
Probable Cause
Out of service
Severity
Critical
Minor
Clear
Additional Info
-
Corrective Action
-
3.2.34 HA
System
Configuration Mismatch Alarm
(Applies to the Mediant 3000)
Table 3-33: HA System Configuration Mismatch Alarm
Description
HA feature is active. The active module was unable to transfer the
License Key to the redundant module.
SNMP Alarm
acHASystemConfigMismatchAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.34
Alarm Title
HA System Configuration Mismatch Alarm
Alarm Source
System#0/Module#<m> where m is the TPM-6310’s slot number
Alarm Type
Processing Error Alarm
Probable Cause
Configuration or customization error
Severity
Major on raise, Clear on clear
Additional Info
-
Corrective Action
-
Содержание LTRT-94602
Страница 22: ......