EMS Alarm Guide
52
Document #: 94602
EMS
3.2.19 SS7
Link
Operational State Changed
Table 3-19: SS7 Link Operational State Changed
Description
Operational state of the link becomes 'IN-SERVICE' or 'OFFLINE'.
*** SS7 *** Link %i is %s $s
%i - <Link number>
%s - <state name>: { 'OFFLINE', 'BUSY', 'INSERVICE'}
%s - IF link has MTP3 layer, then this string equals:
(SP %i linkset %i slc %i)
Where:
%i - <SP number>
%i - <Link-Set number>
%i - <SLC number>
Otherwise there is NO additional text.
SNMP Alarm
acSS7LinkStateChangeAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.19
Alarm Title
SS7 Link State Change Alarm
Alarm Type
communicationsAlarm
Alarm Source
SS7/Link#
Probable Cause
other
Severity
Major,
Clear
Additional Info
-
Corrective Action
For full details, refer to the equipment documentation and the standards
relevant to SS7 MTP3.
Содержание LTRT-94602
Страница 22: ......