Version 3.2
31
October 2007
EMS Alarm Guide
2. Mediant 5000, 8000 Alarms
Table 2-10: Ethernet External Link Alarm
Description
The link between the ES and the external network device has been
established/has failed.
SNMP Alarm
tgEthernetExternalLinkAlarm
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.11
Alarm Title
Ethernet Uplink Alarm
Alarm Source
Board # X
Alarm Type
Communication Alarm
Probable Cause
Loss of signal
Severity
Major for disable, Cleared for enable
Additional Info
Info 1: Mediant 5000 - MG Slots Ethernet links status:1,2 =
00,5..10=00000
Mediant 8000 - MG Slots Ethernet links status:1..8 = 00000000 ,10..18
=00000….
Info 2: ES Ports (ES LEDs) status: 1..26 = 010100101 ……
Corrective Action
If set, check the LED of the port and both fiber cables. Lock and unlock
the port to restart the Ethernet port's auto negotiation process.
2.12 Ethernet
Internal
Link
Alarm
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the Media Gateway have the same standard
structure, including the fields shown in the table.
Содержание LTRT-94602
Страница 22: ......