EMS Alarm Guide
26
Document #: 94602
EMS
Table 2-4: Trunk Alarm
Description
Indicates events/alarms on the T1/E1 trunks in the VoP boards:
Critical: LOS, LOF
Minor: AIS, RAI, RAI_CRC
Major: RED
Minor: BLUE, Yellow
SNMP Alarm
tgTrunkAlarm
SNMP OID
1.3.6.1.4.1.5003.9.1.2.2.0.5
Alarm Title
Trunk Alarm
Alarm Source
Board#X/Trunk#Y
Alarm Type
communicationsAlarm
Probable Cause
degradedSignal
Severity
'LOS' or 'LOF' = 'red alarm' = Major
'AIS' = 'blue alarm' = Major
'RAI' or 'RAI_CRC' = 'yellow alarm' = Minor
Everything is cleared = Clear
Additional Info
Bitmap indicating alarms set/cleared according to the following standard:
1 dsx1NoAlarm
2 dsx1RcvFarEndLOF
4 dsx1XmtFarEndLOF
8 dsx1RcvAIS
16 dsx1XmtAIS
32 dsx1LossOfFrame
64 dsx1LossOfSignal
128 dsx1LoopbackState
256 dsx1T16AIS
512 dsx1RcvFarEndLOMF
1024 dsx1XmtFarEndLOMF
2048 dsx1RcvTestCode
4096 dsx1OtherFailure
8192 dsx1UnavailSigState
16384 dsx1NetEquipOOS
32768 dsx1RcvPayloadAIS
65536 dsx1Ds2PerfThreshold
Corrective Action
If the alarm is set, check its bitmap. If the loopback bit in the
RcvTestCode code alarm - diagnostics is in process, lock and unlock the
trunk for recovery. If the alarm is at the payload level, start looking for the
problem in the MUX equipment. If the AIS alarm bit is set, check the
interfaced equipment. In other cases, check the link quality.