Version 3.2
21
October 2007
EMS Alarm Guide
1. EMS Alarms
1.17 HTTP and HTTPS Disabled Alarm
Table 1-17: HTTP and HTTPS Disabled Alarm
Textual Description
Originated when HTTP access is disabled by EMS hardening but the
EMS manages media gateways that require HTTP access for software
upgrade.
Originated on server startup.
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.17
AlarmTitle
HTTP and HTTPS Dis
ItuAlarmType
Environmental Alarm
AlarmSource
EMS Server
Probable Cause
Application Subsystem Failure
Severity
Major
Additional Info
-
Corrective Action
Separate the gateways between two EMS servers (secured &
unsecured)
Media Gateways
Gateways using the HTTP server for the software upgrade procedure:
MediaPacks, Mediant 1000, Mediant 2000, IPmedia 2000, Mediant
3000, IPmedia 3000
1.18 PM File Generate
Table 1-18: PM File Generate
Textual Description
Originated when a PM file is generated in the EMS server, and it can
be retrieved by a higher level management system.
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.18
AlarmTitle
PM File
ItuAlarmType
Other
AlarmSource
EMS Server
Probable Cause
Other
Severity
Info
Additional Info
The performance summary data from<start polling interval time>
to<timeStempFileTo> of media gateway<nodeIPAdd> was saved in
PM file <fileName>.
Corrective Action
-
Media Gateways
Mediant 5000 / 8000
Содержание LTRT-94602
Страница 22: ......