Version 3.2
49
October 2007
EMS Alarm Guide
3. Mediant 1000/2000/3000, IPmedia 2000/3000 and MediaPack Alarms
3.2.13 ATM Port Alarm
Table 3-15: ATM Port Alarm
Description
ATM Port Alarm. Alarm conditions (taken from the SONET/SDH
standards documents) are:
LOS - Loss of Signal
AIS - Alarm Indication Signal
RDI - Remote Defect Indication
LOS, AIS, and RDI conditions are not present
ATM Port Alarm: port <number>, <text>
SNMP Alarm
acAtmPortAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.13
Alarm Title
ATM Port Alarm
Alarm Type
Equipment Alarm
Alarm Source
ATM Port #
Probable Cause
Adapter error (1)
Severity
Critical
Major
Major
Clear
Additional Info
-
Corrective Action
Ensure that the fiber is plugged into appropriate port on the IPM-6310
Rear Transition Module (RTM) board of the system. Check to see if the
fiber has been damaged. Ensure that the network side of the fiber is
enabled and is on-line.