Version 3.2
55
October 2007
EMS Alarm Guide
3. Mediant 1000/2000/3000, IPmedia 2000/3000 and MediaPack Alarms
3.2.23 SS7
Linkset
Operational State Changed
Table 3-23: SS7 Linkset Operational State Changed
Description
Alarm is sent when Route Set operational state is changed. Alarm is
raised when status is BUSY, and cleared when status is OFFLINE, or
INSERVICE.
*** SS7 *** Linkset %i on SP %i is <'OFFLINE', 'BUSY', 'INSERVICE'>
SNMP Alarm
acSS7LinkSetStateChangeAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.23
Alarm Title
SS7 LinkSet State Change Alarm
Alarm Type
communicationsAlarm
Alarm Source
SS7/SP#/Linset#
Probable Cause
Other
Severity
Major, Clear
Additional Info
-
Corrective Action
For full details, refer to the equipment documentation and the standards
relevant to SS7 MTP3.
3.2.24 SS7
Routeset
Operational State Changed
Table 3-24: SS7 Routeset Operational State Changed
Description
Alarm is sent when Route Set operational state is changed. Alarm is
raised when status is BUSY, and cleared when status is OFFLINE, or
INSERVICE.
*** SS7 *** Routeset %i on SP %i is <'OFFLINE', 'BUSY', 'INSERVICE'>
SNMP Alarm
acSS7RouteSetStateChangeAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.24
Alarm Title
SS7 Route Set State Change Alarm
Alarm Type
communicationsAlarm
Alarm Source
SS7/SP#/RouteSet#
Probable Cause
Other
Severity
Major, Clear
Additional Info
-
Corrective Action
For full details, refer to the equipment documentation and the standards
relevant to SS7 MTP3.
Содержание LTRT-94602