Version 3.2
47
October 2007
EMS Alarm Guide
3. Mediant 1000/2000/3000, IPmedia 2000/3000 and MediaPack Alarms
Table 3-12: Ethernet Link Down or Remote Ethernet Link Down
Description
Ethernet link is down or remote Ethernet link is down and the board has
no communication to any other host.
No link at all.
Link is up again.
Primary link is down only - 'Primary Link is lost. Switching to
Secondary Link'
SNMP Alarm
acBoardEthernetLinkAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.10
Alarm Title
Ethernet Link Down
Alarm Type
Equipment Alarm
Alarm Source
Probable Cause
Input/Output Device Error
Other
Underlying resource unavailable
Severity
Critical
Cleared
Major
Additional Info
-
Corrective Action
Ensure that both Ethernet cables are plugged into the back of the
system. Inspect the system's Ethernet link lights to determine which
interface is failing. Reconnect the cable or fix the network problem.
3.2.11 System
Component Overloaded
The table describes the alarm and shows the alarm information presented to Users. For
Users' convenience, all alarms generated by the device have the same standard structure,
including the fields shown in the table.
Содержание LTRT-94602