EMS Alarm Guide
48
Document #: 94602
EMS
Table 3-13: System Component Overloaded
Description
Overload in one or more of the system's components
SNMP Alarm
acBoardOverloadAlarm
SNMP OID
1.3.6.1.4.1.5003.9.10.1.21.2.0.11
Alarm Title
System Component Overloaded
Alarm Type
Other
Alarm Source
'GWAPP'
Probable Cause
Other
Severity
Major / Clear
Additional Info
-
3.2.12 Alarms Table Overflow
Table 3-14: Active Alarm Table Full
Description
Alarm is raised when too many alarms to fit in the active alarm table. The
status stays major until reboot as it denotes a possible loss of information
until the next reboot. If an alarm was raised when the table was full, it is
possible that the alarm is active, but does not appear in the active alarm
table.
SNMP Alarm
acActiveAlarmTableOverflow
SNMP OID
1.3.6.1.4.15003.9.10.1.21.2.0.12
Alarm Title
Active Alarm Table Overflow
Alarm Type
Processing Error Alarm
Alarm Source
MG
Probable Cause
resourceAtOrNearingCapacity (43)
Severity
Major
Additional Info
-
Corrective Action
Some alarm information may have been lost, but the ability of the device
to perform its basic operations has not been impacted. A reboot is the
only way to completely clear a problem with the active alarm table.
Contact your first-level group.