Version 3.2
19
October 2007
EMS Alarm Guide
1. EMS Alarms
1.13 Software
Upgraded
Table 1-13: Software Upgraded
Textual Description
Indicates Mediant 5000 / 8000 Online Software Upgrade procedures
and version information.
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.13
AlarmTitle
EMS Server Started
ItuAlarmType
Equipment Alarm
AlarmSource
EMS Server
Probable Cause
Version Mismatch
Severity
Info
Additional Info
Started / Finished / Aborted
Corrective Action
No action should be taken; this is an information alarm
Media Gateways
Mediant 5000 / 8000
1.14 Software
Replaced
Table 1-14: Software Replaced
Textual Description
Originates when the EMS discovers a software version replace
between board versions, for example, from V4.6.009.004 to
V4.6.152.003 (when both versions are managed by the EMS).
Software Replace old version : <old version> new version <new
version>
SNMP OID
1.3.6.1.4.1.5003.9.20.3.2.0.14
AlarmTitle
EMS Server Started
ItuAlarmType
Communications Alarm
AlarmSource
EMS Server
Probable Cause
Other
Severity
Info
Additional Info
If you initiated a performance measurements polling process before
you initiated the software replacement process,the polling process is
stopped.
Corrective Action
No action should be taken; this is an information alarm.
Media Gateways
All the gateways managed by the EMS.
Содержание LTRT-94602