CONFIGURATION
88M – Mains Reference Voltage
Range:
100 – 14000 V
D
Default:
400 V
Description:
Provides the reference voltage for the analog output and performance graphs.
9 Motor Data-2
The MVS can support two different starting and stopping motor data sets.
To select the secondary motor data set, a programmable input must be configured to parameter set selection
(parameters 6A and 6F) and the input must be active when the soft starter receives a start signal.
NOTE
You can only choose which motor data set to use while the soft starter is stopped.
9A ~ 9E – Secondary Motor Settings
Parameter 9A
Reserved
This parameter is reserved for future use.
Parameter 9B
Motor FLC-2
Range:
5 - 1000 A
D
Default:
100 A
Description:
Sets the secondary motor's full load current.
Parameter 9C
Reserved
This parameter is reserved for future use.
Parameter 9D
Reserved
This parameter is reserved for future use.
Parameter 9E
Reserved
This parameter is reserved for future use.
10 Start/Stop-2
10A ~ 10I – Start/Stop-2
Refer to Start/Stop-1 (parameters 2A~2I) for details.
Parameter 10A
Start Mode-2
Options:
Constant Current (default)
Description:
Selects the soft start mode.
Parameter 10B
Start Ramp-2
Range:
0:01 - 3.00 (minutes:seconds)
D
Default:
1 second
Description:
Sets the ramp time for current ramp starting (from the initial current to the current
limit).
Parameter 10C
Initial Current-2
Range:
100% - 600%
D
Default:
400%
Description:
Sets the initial start current level for current ramp starting, as a percentage of motor full
load current. Set so that the motor begins to accelerate immediately after a start is
initiated.
If current ramp starting is not required, set the initial current equal to the current limit.
Parameter 10D
Current Limit-2
Range:
100% - 600% FLC
D
Default:
400%
Description:
Sets the current limit for constant current and current ramp soft starting, as a
percentage of motor full load current.
Parameter 10E
Reserved
Description:
This parameter is reserved for future use.
Parameter 10F
Kickstart Time-2
Range:
0 - 2000 (milliseconds)
D
Default:
0000 milliseconds
Description:
Sets the kickstart duration. A setting of 0 disables kickstart.
54
MVS Panel User Manual
710-13937-00C
Содержание MVSxxxx-V02