If the auxiliary port cover is labeled "Auxiliary Port" than the factory hardware upgrade has been
completed. If you are still unsure or have questions about the hardware upgrade please feel free
to contact us.
Figure 62: Auxiliary Port Label
4.2.6.3.2 Removing the Auxiliary Port Cover
Prior to installing an auxiliary sensor you will need to remove one of the auxiliary port covers. To
identify which auxiliary port cover you need to remove please refer to the installation instructions for
your specific device. The removal instructions are the same for both auxiliary port covers.
To remove the auxiliary port cover on your tow fish you will need the following tools and supplies
that were supplied with the system and auxiliary sensor.
·
3/32" Hex Key Driver (Supplied with auxiliary sensor)
·
5/32" Hex Key Driver
·
1/4-20 Screw 2ea. (Supplied with auxiliary sensor)
Complete the following steps to remove the auxiliary port cover.
·
Using the 3/32" and 5/32" Hex Key Driver remove the two auxiliary port cover screws. Retain the
screws for use with the auxiliary sensor or to reinstall the auxiliary port cover.