ATLAS North America Proprietary
Sea Scan® ARC Explorer™ Manual
1 of 1
Page: 24
Issue: 4.2.1
2SFT1-0001
Manual
Figure 28: Towrail adjustment screw
·
Next, grab both ends of the towrail and slide it left (starboard side) or right (port side).
Figure 29: Towrail in an Angled Position
·
W hen you reach the desired angle, tighten both screws.
4.2.3.2
Zeroing Procedure
To return the towfish to normal center, follow this procedure.
·
Follow the adjustment procedure back to the marked 0 position.
·
Lift the towfish by the rigged towcable while checking the roll measurement on the Sea
Scan®Survey program to determine if it is at the correct angle.
·
Adjust the rail by the appropriate amount to set the center, rechecking with the above method
until 0 is found.
4.2.4
Tranducers
The field-changeable transducers help make the ARC Explorer unique and unequaled in
customization. The system arrives with a single towfish and a pair of transducers, but multiple sets
of transducers are available and allow customization of the towfish, however needed. For example,
one side can be set at 600/1200 kHz and the other at 900/1800 kHz, etc. This system can fit
almost any side-scan sonar need.