ATLAS North America Proprietary
Sea Scan® ARC Explorer™ Manual
1 of 1
Page: 17
Issue: 4.2.1
2SFT1-0001
Manual
TIP:
If you have a dual-frequency towfish, the rub check must be done separately for each
frequency
.
3.1.7
Packing Up
3.1.7.1
Software
·
In Sea Scan Survey, open the sonar Control W indow and turn the power <Off>.
·
You can close the software at this point. This action will close the survey, which will be stored on
your computer’s hard drive in the "My Sonar Data" folder.
3.1.7.2
Hardware
CAUTION:
Turn off the TCU BEFORE unplugging the towfish! Failure to do so can result in a
damaged towfish or TCU!
·
Disconnect the power cable from the power source and then from the TCU.
·
Disconnect the tow cable from the towfish.
CAUTION:
Verify that the connectors are dry. If water is inside the connector, a quick blow of air
from either a can of compressed air or a spray of W D-40™ should be sufficient to avoid corrosion.
·
Disconnect the towfish cable from the TCU.
·
Disconnect the Ethernet cable from the TCU and then the computer.
·
Put on any connector covers on the ends of the system cables.
·
Be sure to rinse anything that came in contact with salt water with clean fresh water before storing
the system.
4
ARC Explorer System Hardware
4.1
Topside Communications Unit (TCU)
Marine Sonic Technology has designed the Topside Communications Unit (TCU) for ease of use.
The unit housing is sealed and made of rugged plastic. All connectors are water resistant.
Indicator lights are on the front of the unit to indicate power to the unit, communication with the
network, and communication with the towfish. Internal circuit boards seamlessly communicate with
all attached components, and an internal power supply provides the voltage for the towfish.