Asentria SiteBoss 530 User Manual
2
CONTENTS:
Please inventory the package contents and ensure you have the following items pertaining to the -48VDC Power
Option:
1.
A cable harness consisting of 2 red and 2 blue wires connected to a white nylon “Molex” connector.
2.
A bare white nylon housing.
3.
5 crimp-on contacts.
-48VDC CONNECTION:
The -48VDC power supply option has 4 input connections.
This gives the user the ability to connect this unit to an auxiliary
-48VDC power source. Note: The dark area on the diagram
represents the latching mechanism on the housing.
DANGER! FIRE HAZARD!
DO NOT LEAVE AN UNCONNECTED WIRE EXPOSED!
DO NOT CONNECT THE UNIT TO ANY OTHER EQUIPMENT UNTIL YOU KNOW THE UNIT POWERS UP
CORRECTLY!
Option A
: Connect the supplied harness assembly to your -48VDC voltage source:
1.
Ensure the unit is not connected to any peripheral equipment.
NOTE:
Peripheral equipment connections may cause a short circuit of your -48V supply if the power
connections are reversed! Do not connect peripheral equipment connections until you know the unit is
operational by observing the front panel Power LED.
2.
Strip the ends of the wires.
3.
Using wire nuts (not supplied), connect the stripped wires to the power source. The red wires connect to
ground or the most Positive connection on the voltage source. The blue wires connect to -48VDC or the most
Negative connection on the voltage source.
Option B:
Use the supplied kit to make a wire harness:
1.
You will need a crimping tool that crimps standard Molex type 18-24 AWG Mini-Fit Terminals (Molex Part
Number: 39-00-0060, Engineering Series 5556).
2.
Crimp the supplied terminals to your cable connections.
3.
Insert the crimped terminals into the supplied white nylon housing. Orient the housing so the latching
mechanism is up and you are looking into the large end of the housing. See diagram above. Insert the 2
Ground or Most Positive leads into the upper and lower compartments on the left side of the connector, e.g.
the same positions as the black wires on the supplied harness assembly. Insert the 2 -48VDC or Most
Negative leads into the upper and lower compartments on the right side of the connector, e.g. the same
positions as the white leads on the supplied harness assembly.
4.
Connect the completed assembly into the power input receptacle at the rear of the unit.
- 4 8 V D C B L U E
G N D R E D
- 4 8 V D C B L U E
G N D R E D