When the channel 1 is configured as input mode:
The C1DT is the CVAL value stored by the last channel
1 input event (C1IN)
When the channel 1 is configured as output mode:
C1DT is the value to be compared with the CVAL value.
Whether the written value takes effective immediately
depends on the C1OBEN bit, and the corresponding
output is generated on C1OUT as configured.
14.5.4.13
TMR16 and TMR17 break register (TMRx_BRK)
Bit
Register
Reset value
Type
Description
Bit 31: 17
Reserved
0x0
resd
Kept at its default value.
Bit 19: 16
BKF
0x0
rw
Brake input filter
This field is used to set the filter for break input. The filter
number N indicates that the input edge can pass through
filter only after N sampling events.
0000: f_SAMPLING=f_DTS (no filter)
1000: f_SAMPLING=f_DTS/8, N=6
0001: f_SAMPLING=f_(CK_INT), N=2
1001: f_SAMPLING=f_DTS/8, N=8
0010: f_SAMPLING=f_(CK_INT), N=4
1010: f_SAMPLING=f_DTS/16, N=5
0011: f_SAMPLING=f_(CK_INT), N=8
1011: f_SAMPLING=f_DTS/16, N=6
0100: f_SAMPLING=f_DTS/2, N=6
1100: f_SAMPLING=f_DTS/16, N=8
0101: f_SAMPLING=f_DTS/2, N=8
1101: f_SAMPLING=f_DTS/32, N=5
0110: f_SMPLING=f_DTS/4, N=6
1110: f_SAMPLING=f_DTS/32, N=6
0111: f_SAMPLING=f_DTS/4, N=8
1111: f_SAMPLING=f_DTS/32, N=8
Bit 15
OEN
0x0
rw
Output enable
This bit acts on the channels as output. It is used to enable
CxOUT and CxCOUT outputs.
0: Disabled
1: Enabled
Bit 14
AOEN
0x0
rw
Automatic output enable
OEN is set automatically at an overflow event.
0: Disabled
1: Enabled
Bit 13
BRKV
0x0
rw
Break input validity
This bit is used to select the active level of a break input.
0: Break input is active low.
1 Break input is active high.
Bit 12
BRKEN
0x0
rw
Break enable
This bit is used to enable break input.
0: Break input is disabled.
1: Break input is enabled.
Bit 11
FCSOEN
0x0
rw
Frozen channel status when holistic output enable
This bit acts on the channels that have complementary
output. It is used to set the channel state when the timer
is inactive and MOEN=1.
0: CxOUT/CxCOUT outputs are disabled.
1: CxOUT/CxCOUT outputs are enabled. Output inactive
level.
Bit 10
FCSODIS
0x0
rw
Frozen channel status when holistic output disable
This bit acts on the channels that have complementary
output. It is used to set the channel state when the timer
is inactive and MOEN=0.
0: CxOUT/CxCOUT outputs are disabled.
1: CxOUT/CxCOUT outputs are enabled. Output idle
level.
Bit 9: 8
WPC
0x0
rw
Write protection configuration