17
Remove the 5 screws S1 to S5 by
using a Phillips PH1 screwdriver
and open the back of the HD-
IVS-ST.
→
Photo
Remove the 3 screws S1 to S3 by
using a Phillips PH1 screwdriver
to open the top of the optics
assembly.
→
Photo
Remove the cover by using a
1.5 mm hex key.
→
Photo
Disconnect the connector
→
Photo
by using a pair of tweezers and
pull out the cable carefully through
the top of the optics assembly.
→
Photo
Turn the focus screw S1
→
Photo
clockwise by using a 1.5 mm hex
key until the lens comes loose and
pull it out carefully. Make sure the
connector slips through the
housing, without being pulled.