![Arctic Cat DVX 400 2004 Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/arctic-cat/dvx-400-2004/dvx-400-2004_service-manual_2965348150.webp)
6
Electrical
Problem: Spark absent or weak
Condition
Remedy
1.
Ignition coil
defective
2.
Spark plug
defective
3.
Magneto
defective
4.
CDI unit
defective
5.
Pick-up coil
defective
1. Replace ignition coil
2. Replace plug
3. Replace magneto
4. Replace CDI unit
5. Replace pick-up coil
Problem: Spark plug fouled with carbon
Condition
Remedy
1.
Mixture
too rich
2.
Idling RPM
too high
3.
Gasoline
incorrect
4.
Air cleaner element
dirty
5.
Spark plug
incorrect (too cold)
6.
Valve seals
cracked - missing
7.
Oil rings
worn - broken
1. Adjust carburetor
2. Adjust carburetor
3. Change to correct gasoline
4. Clean element
5. Replace plug
6. Replace seals
7. Replace rings
Problem: Spark plug electrodes overheat or burn
Condition
Remedy
1.
Spark plug
incorrect (too hot)
2.
Engine
overheats
3.
Spark plug
loose
4.
Mixture
too lean
1. Replace plug
2. Service cooling system
3. Tighten plug
4. Adjust carburetor
Problem: Magneto does not charge
Condition
Remedy
1.
Lead wires/connections
shorted - loose - open
2.
Magneto coils
shorted - grounded - open
3.
Regulator/rectifier
shorted - punctured
1. Repair - replace - tighten lead wires
2. Replace magneto coils
3. Replace regulator/rectifier
Problem: Magneto charges, but charging rate is below the specification
Condition
Remedy
1.
Lead wires
shorted - open - loose (at terminals)
2.
Stator coils (magneto)
grounded - open
3.
Regulator/rectifier
defective
4.
Cell plates (battery)
defective
1. Repair - tighten lead wires
2. Replace stator coils
3. Replace regulator/rectifier
4. Replace battery
Problem: Magneto overcharges
Condition
Remedy
1.
Internal battery
short circuited
2.
Regulator/rectifier resistor
damaged - defective
3.
Regulator/rectifier
poorly grounded
1. Replace battery
2. Replace resistor
3. Clean - tighten ground connection
Problem: Charging unstable
Condition
Remedy
1.
Lead wire
intermittently shorting
2.
Magneto
internally shorted
3.
Regulator/rectifier
defective
1. Replace lead wire
2. Replace magneto
3. Replace regulator/rectifier
Problem: Starter button not effective
Condition
Remedy
1.
Battery charge
low
2.
Switch contacts
defective
3.
Starter motor brushes
not seating
4.
Starter relay
defective
5.
Emergency stop - ignition switch
off
6.
Wiring connections
loose - disconnected
7.
Clutch position switch
defective
1. Recharge - replace battery
2. Replace switch
3. Repair - replace brushes
4. Replace relay
5. Turn on switches
6. Connect - tighten - repair connections
7. Replace switch
Problem: Battery discharges too rapidly
Condition
Remedy
1.
Electrical
load too high
2.
Battery
short-circuited
1. Reduce electrical load
2. Replace battery
Problem: Battery polarity reversed
Condition
Remedy
1.
Battery
incorrectly connected
1. Reverse connections - replace battery
Содержание DVX 400 2004
Страница 1: ...ATV Service Manual 2004 2004 2004 A A RC C C T T I DVX 400...
Страница 15: ...8 ATV2152...
Страница 16: ...9 ATV2153...
Страница 80: ...9 Oil Flow Chart ATV2180...
Страница 89: ...18 NOTES...
Страница 103: ...14 WIRING DIAGRAM Harness p n 3509 007 Insert Fold Out 0739 430...
Страница 104: ...1 SECTION 6 DRIVE SYSTEM Table Of Contents Drive System 6 2 Rear Drive Assembly Schematics 6 2 Rear Drive Axle 6 3...
Страница 109: ...6 NOTES...
Страница 126: ...1 SECTION 8 STEERING FRAME Table Of Contents Steering Post Tie Rods 8 2 Measuring Adjusting Toe In Toe Out 8 7 Body 8 8...
Страница 135: ...10 SP106 SP107 7 Install the starter relay then install the seat making sure it is locked securely front and rear...
Страница 153: ......