Sets Date and Time for the real-time clock. Time is always set to standard
time. Use the #DAY command to adjust for daylight saving time.
yyyy
=
Year
mm
=
Month
dd
=
Day
hh
=
Hour
mm
=
Minute
ss
=
Second
A.3.49
Timer Configuration, Set or Return (TCF)
Command:
d#,f#,h#,at#,bt#,s/r#TCF
Returns or sets the parameters necessary for timer operation.
d#
Display
f#
Function
0
Seconds
0
Time A to B
1
Cycles (50Hz)
1
Time A for X Counts
2
Cycles (60Hz)
2
Time width of A
3
Cycles (Ch1 Hz)
3
Frequency of A
4
Count A Events
5
Count A events gated by B
h#
Hold mode on stop
0
Disable
1
Enable
at#
A Trigger
bt#
B Trigger
0
DC Applied
0
DC Applied
1
DC Removed
1
DC Removed
2
AC Applied
2
AC Applied
3
AC Removed
3
AC Removed
4
Contact Open
4
Contact Open
5
Contact Closed
5
Contact Closed
s/r#
Set or Return Value
0
Set Value
1
Return Value
A.3.50
Transducer Display (TDU)
Command:
TDU
Displays Transducer Quantities as set up using transducer configuration
(COT). Starts transducer operation.