A.3.25
Overload Status (OVD)
Command:
OVD
Returns:
Value
Status
0
No overload
1
Channel 1 overload
2
Channel 2 overload
3
Both Channels 1 and 2 overload
A.3.26
Phase/Frequency Display (P F)
Command:
P F
Displays Channel 1 frequency and the phase angle of Channel 2 relative
to Channel 1. Uses Channel 1 as an internal reference. When measuring
a voltage and a current, use Channel 1 for the voltage and Channel 2 for
the current.
A.3.27
Power/Vars Display (P V)
Command:
#P V
Displays the active and reactive power of the signals on Channels 1 and 2.
Set Channel 1 to measure AC voltage and Channel 2 AC current.
#
To select
0
(or absent) Power, Vars
1
Watt hours, Var hours
A.3.28
Power Factor, Return (PFA)
Command:
PFA
Returns the power factor of Channel 1 and 2 together. Channel 1 must be
set to measure AC voltage and Channel 2 AC current. In 3 phase mode,
returns the average of the individual power factors.
Response: Numeric ASCII string.